The Huber Suhner 3400.17.0230 is a quarterwave lightning suppressor designed to protect electronic equipment from damage caused by lightning strikes. This suppressor works by diverting the excess energy from a lightning strike away from the connected equipment, preventing damage and potential downtime. It is designed to be used in conjunction with a grounding system to provide maximum protection.
Maintenance-free products
Best PIM performance
Aeronautical Radionavigation
Aviation Radio Navigation Service
Radio Navigation Satellite Service
Global Navigation Satellite Service
Compact form factor
Specifications | |
Product configuration | |
| Main path connectors | Port 1: unprotected, N jack (female) Port 2: protected, N jack (female) |
| Mounting and grounding | MH50 (bulkhead mounting) |
| Side of bulkhead | Protected side |
| EMP can be install reversed | YES |
Interface and material data | |
| Housing material / plating | Brass / SUCOPLATE (R) Plating |
| Center contact, material / plating | Port 1: Copper Beryllium Alloy / SUCOPRO Plating Port 2: Copper Beryllium Alloy / SUCOPRO Plating |
Electrical data | |
| Impedance | 50 Ω |
| Frequency frame | 824 MHz to 1990 MHz |
| Return loss typical | ≥ 20 dB |
| Insertion loss typical | ≤ 0.15 dB |
| CW power frame | ≤ 400 W |
| Peak power frame | ≤ 1000 W |
| PIM 3rd order | -150 dBc max. |
| Residual pulse energy (typ.) | 5 µJ (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) |
| Surge current handling capability | 50 kA multiple (test pulse 8/20 µs) 25 kA multiple (test pulse 10/350 µs) |
Electrical remarks | |
| Gas tube | No DC / shorted QW or LC |
Mechanical data | |
| Weight | 224 g |
| Mating cycles | 500 |
Environmental data | |
| Operation temperature | -40 °C ... 85 °C |
| Storage temperature | -40 °C ... 85 °C |
| Ingress protection (IP Rating) | Mated / IP66, according to IEC 60529 |
| Thermal shock according | MIL-STD-202, Method 107, Cond. B |
| Vibration according | MIL-STD-202, Method 204, Cond. A |
| Moisture resistance according | MIL-STD-202, Method 106 |